Presence sensor with an integrated Triac dimmer, combining PIR, microwave radar and a light sensor.
Item
Detail
Model
SSI
Category
Smart sensor
02 Features
A smart presence-sensor switch, ceiling or wall mounted, that automatically controls the connected electrical devices when someone is detected.
Flexible applications: supports both standard ON/OFF devices and Triac-dimmable lighting systems.
Built-in Raptortron Mesh technology for seamless connection to the smart home automation system.
Complete remote management, control and calibration through the Raptortron mobile app.
Operating schedules and advanced automation rules can be set.
Combines a PIR infrared sensor, microwave radar and a light sensor to improve accuracy and minimise false triggering.
03 Technical specifications
01 Design & dimensions
Specification
Value
Glass colour
Black / White
Bezel colour
Silver / Gold
Dimensions
86mm x 86mm x 30mm
Compatible flush box
75mm x 75mm
02 Sensing & measurement
Specification
Value
Built-in sensor types
PIR motion sensor, radar presence sensor, ambient light sensor
03 Control interface
Specification
Value
Control type
01 channel with 02 output options: Relay or Triac Dimmer
Touch control
02 keys: 01 ON/OFF key and 01 Auto/Manual mode key
04 Power & load
Specification
Value
Input voltage
80 VAC ~ 240VAC / 50~60Hz
Resistive load rating
5A/channel Relay or 300W/channel Dimmer
LED load rating
150W/channel Relay or 150W/channel Dimmer
Maximum inrush current
10A/channel Relay or 5A/channel Dimmer
Standby power consumption
< 1W
Protective fuse
20A
05 Connectivity
Specification
Value
Wireless communication
Raptortron Mesh
Wireless range
100m open air / 30m indoor
06 Indicators & alerts
Specification
Value
Status indicator LED
Blue
Night locator light
Yes
Audible alert
Yes
04 Installation guide
Front view. Keys 1 and 2; plate 86 mm x 86 mm.Wiring diagram (rear view of the sensor body).
Diagram legend
Mark
Meaning
1
ON/OFF
2
Auto/Manual
L-IN
Live wire supplying power to the device.
Load Output (R)
Load output: connects to the controlled device (light, relay).
Triac Dimmer Output
Triac dimmer output: controls the brightness of dimmable lights.
N-IN
Neutral wire supplying power to the device.
FUSE
Protective fuse: breaks the circuit when the current exceeds the safe limit.
Ceiling Mount Clip
Spring clip that holds the device in the ceiling flush box.
In the box
Raptortron sensor
Touch glass panel with bezel
Wall screws (if needed)
Quick guide & warranty card
Installation steps
Choose the location. Place the sensor in a position that suits the detection range of the product (see Technical specifications for details).
Switch off the power. Turn off the main circuit breaker for the area where the switch is installed. Use a voltage tester to confirm that there is no power at the switch location.
Connect the wires. Connect the L (Live) and N (Neutral) wires to the matching terminals on the switch body. For a switch that controls loads: connect the load wire (L-out) to the device. For a curtain switch: connect the 2 dry contacts (NO) to the Open/Close motor.
Mount in the flush box. Place the switch body in the 75×75mm flush box and tighten the 2 screws evenly; make sure the face sits flat against the wall.
Fit the glass panel. Align the touch glass panel with the body and press all 4 corners evenly until it clicks into place; fit the decorative bezel on the outside.
Restore power. Switch the circuit breaker back on. The indicator LED lights up and the device enters standby, waiting to be connected.
05 Connection guide
Preparation
Raptortron smart switch
1 central hub with an Internet connection
Raptortron app already connected to the central controller (make sure the phone and the central controller are on the same Internet network)
Download the Raptortron app for Android or iOS.
In the Raptortron app: auto learn
Tap. Open the Raptortron app, tap the "Menu" icon at the top of the screen, then select "Devices".
Tap. Tap the "Auto learn" icon.
Tap. When the "Auto learn" dialog appears, tick the "I have understood and agree" box, then tap "OK" to confirm.
The system starts a 60-second countdown to scan automatically and complete the device connection.
Important
Auto learn fails if the number of devices exceeds the capacity limit of the central controller.
In that case, see the Technical specifications of the central controller for the number of devices allowed, or switch to the manual learn method.
In the Raptortron app: manual learn
Open the "Menu" in the app, then go to "Devices".
Press and hold. Press and hold the icon of the device that you want to re-learn or replace.
In the list of options that appears, select "Manual learn".
Tap. When the "Manual learn" dialog appears, tap the "Learn" button.
The dialog shows the Device code and the Serial number of the device.
The app counts down 60 seconds to finish synchronising and remembering the new device.
Teaching the device ID to the central controller
Do this on the device while the app is counting down.
Press and hold. Press and hold key "1" to enter the MENU.
Press. Press key 1 to teach the ID.
Make sure the MCE is in ID-teaching mode.
Key positions.
Result
If the ID is taught successfully: the device exits automatically.
If teaching the ID fails: the green LED keeps blinking. To try again, press key 1, or press and hold key 2 to exit.
06 Safety notes
Use only a power supply that matches the technical specifications in this document. Using the wrong power supply can damage the device and be dangerous.
Do not open or repair the device while it is powered. All electrical wiring must be done by a qualified electrician.
Keep the device in a dry place, away from direct water splashes (except models explicitly rated as water-resistant, IP xx).
The product is covered by the official Raptortron warranty policy. Please keep your purchase invoice for the best support.
Raptortron SSI user manual. English edition translated in full from the manufacturer's original manual. Specifications are subject to change as firmware and hardware are refined; the product page lists the current data. Questions: contact Raptortron.